BOV Not Closing – NX30 March 1, 2017 admin How Can We Help? Search PostedMarch 1, 2017Last Updated OnMarch 1, 2017Byadmin You are here: KB Home Blow Off Valve BOV Not Closing - NX30 < BackProblem The BOV will not close when it is supposed to Cause BOV wired with 24VDC, needs to be 120VAC Solution Correct the wiring error. Table of Contents